RMTSVC2.4.6A.rar application description

xiaoxiao2021-03-06  106

RMTSVC2.4.6A.rar submission time: 2004-06-02 Submit users: YYC123 Tool Category: Network Tool Running Platform: Windows Tool Size: 199499 BYtes Files MD5: 05888F841162CF5E93CB923A46327B1B Source: http: //yycnet.yeah.NetrMTSVCCNET.4. 6 Instructions for use Build20040601 RMTSVC & VIDC is a remote control tool for FTP services, Telnet services, Proxy services, and VIDC services. Users can control remote computers through this tool. This tool is different from other remote control tools. Installing the B / S structure, the user can remotely control through the browser, and the client browser can be any browser that supports HTML3 and above, such as IE4.0 and above, Mozilla browser, Netscape7.0, etc. This tool has the following functions: 1. File upload download. The RMTSVC itself has an FTP service, supports breakpoints, Port / PASV mode, and users can download and download files with any FTP client tools and IE browser. 2, remote control function. Users can remotely operate the controlled machine through the browser, including remote login, logout, shutdown, lock mouse keyboard, display password box content. 3, process / module browsing. Display the operating system information of the remote computer, the Administrator password, the process / module list, kill the specified process, change the process priority, display the CPU / memory occupancy of the remote computer in real time. 4, proxy service. RMTSVC itself has a proxy service function, supports HTTPS, SOCKS4 / SOCKS5 Agents, supports proxy verification / anonymous access, etc. 5, Telnet service. Let users control the machine through the Telnet remotely. 6, VIDC service. RMTSVC2.4.5 integrates a VIDC function. It itself is both a VIDC server is also a VIDC client. This tool user can easily implement the release of the intranet service and the intranet control intranet. 7, the process is hidden, the abnormal automatic restart, kill the specified process, etc. 8. Support for file management, upload, download ... 1. RMTSVC operation and parameter description RMTSVC is a Win32 console program that can double-click to run directly or run automatically after the Windows service is turned on. Usage: Rmtsvc.exe [Options]. The meaning of the RMTSVC running parameters in detail below. -I: Install the RMTSVC service. When you run this parameter, the program will automatically install the RMTSVC as a Windows system service, and then the RMTSVC will automatically run after each boot. You can also enter the RMTSVC's control interface (via browser), install RMTSVC as a service. Detailed description of the following RMTSVC Control Interface Option menu is described in: Uninstall the RMTSVC service. Do not install the RMTSVC as a Windows system service so that the RMTSVC will not run automatically after the next boot is turned on. -S: Start the RMTSVC service. If the user installs the RMTSVC service, you can start the RMTSVC program through this parameter, running as a service. Of course, the user can also start the RMTSVC service through the Windows Service Management Console (SMC). -E: Stop RMTSVC service.

If the user installs the RMTSVC service and launches the RMTSVC service, stop the RMTSVC service through this parameter or stop the RMTSVC service through the Windows Service Management Console (SMC), and the premise is of course the installer allows you to stop the RMTSVC service via the SMC or console. If the user is set to notify the RMTSVC service via the SMC and console, you will not be able to stop the RMTSVC service. Detailed description of the following RMTSVC Control Interface Option menu is shown. -D: Run the RMTSVC program in the Debug mode. This parameter can specify the debug level 1-4 to control the debug information level output when RMTSVC runtime. For example, -D4 outputs any level of debugging information, and -d1 only outputs a few important debug information. Under this mode, run the RMTSVC can easily observe the health of the RMTSVC, and the user can end the RMTSVC program to run through Ctrl C. -F: Run the RMTSVC program in a later manner. At this point, RMTSVC acts as a Faceless console program. When the console window is turned off, the RMTSVC will not end. You can only pass the management interface. The default user directly double-click Run RMTSVC.exe to run in this way (if the user has installed the RMTSVC to the service, double-click Run will run as a service mode, which is equivalent to -s parameter) -p: Specify the RMTSVC service port, if I don't specify the default service port 7778. Second, if you enter the RMTSVC management interface and control the remote computer RMTSVC is a B / S remote control tool, users do not need to install the client, remote management and control operations can be performed through the browser. When RMTSVC is running on the controlled machine, you can access the coated controlled machine on any of the machines that can access the controlled machine. Open the browser to enter http: // ip: port. Where IP is the IP address of the controlled machine, Port is the RMTSVC service port, if you have not changed the service port, the default port will be 7778. After connecting the controlled machine, you will see a welcome login screen, ask you to enter the password to access the RMTSVC service. If you have not changed the password, then the default access password is 123456. You can do it after entering the correct password. Any operation of any RMTSVC support. Welcome to the top of the RMTSVC system menu. Includes the following menu options: PView - Process View. With RMTSVC, you can remotely manage the process, display the information of the remote system, the Administrator user password, the CPU / memory spending, etc. SPY - Remote control management. The controlled machine is remotely controlled via the browser. Proxy - Start or stop the RMTSVC's proxy service, set the operational parameters of the proxy service. FTP & Telnet - Start or stop the RMTSVC's FTP service / Telnet service, configure the service run parameters. VIDC - Sets access to VIDCs. Set up VIDCC connection parameters, mapping ports, and the like. Logoff - Log in to RMTSVC. Option - Configure RMTSVC's running parameters, such as access passwords, hide, etc. IsOut - RMTSVC Welcome / login screen. Third, the PVIEW process manages users Enter the password to log in and click the PVIEW menu to enter the RMTSVC remote process management interface. This page will display three parts: system information, process / module information, CPU / memory usage information. System Information: The system information will display the computer name of the remotely controlled machine, operating system / version / packs. CPU type. Display Remote Control Machine Current login account and password, format: machine name / account / password.

Note that this feature is only valid for NT / 2000, which is invalid for Win9x and XP. If the remote controlled machine is not logged in, you cannot display the current login account and password. If you run RMTSVC in a service, you can only display the password of the system administrator (Administrator). If you run in a non-service, you can display the current account and password currently logged in. Process / Module Information: Displays all processes running on the current controlled machine, the right side of the page is the process module display area, click a process name to display the related module information of this process. At this point, click the "Kill IT" button to kill the current process. Note that the list will not be automatically refreshed in real time, and the user must manually refresh. CPU / Memory Using Information: The graphics in the upper right corner of the page displays a graph of the CPU usage of the currently controlled machine, and the green line is the CPU usage yellow line to take up green. Click on the graph to stop / continue to display the graph in real time. Fourth, SPY Remote Control Manager After entering the password After logging in, click the SPY menu to enter the RMTSVC remote process control interface. You can easily control the remote machine via RMTSVC, just like the local machine. The lower side of the remote control interface is a control tool area, divided into three pieces: the quality, size of the image is set on the left. Quality: Poor (Poor) FAIR (Normal) GOOD (Clear) Set the quality of the capture image, the better the quality of the image, the larger the amount of data. Stretch: Set the reduction ratio (30, 50, 80, 100%) of the capture image, the default image is 100%, and the capture screen image is not reduced. CURSOR: Whether to capture the mouse cursor when capturing a remote computer screen so that the user knows the current mouse cursor position. The default is not captured. Set: Determines the button, the above three parameters set by the user take effect. Middle section: Displays the current controller's mouse location and mouse action information. When the user's mouse moves and acts at the controlled machine screen image, the user's current action and the mouse position are displayed. LButton RButton Mbutton indicates that the current mouse action is the left mouse button / right / or the middle key, the Click DBClick indicates that the current mouse action is a click or double click. Ctrl Shift Alt Indicates whether the Ctrl Shift Alt key is pressed when the mouse action or keyboard is entered. Drag DROP remote drag operation, analog mouse drag, for example, if you want to drag an icon for the remote desktop, then you can check Drag from the mouse action control area, then click the Remote Desktop to want to drag the icon, Then click on the destination position of the drag, and the other drag and drop is similar. (This is a bit of trouble, there is a friend asking why you can't operate more than other mouse action, I also do more on the screen image, I also want to do this, but the browser front-end script does not support mouse drag events) ONLY MOVE : Move only mouse. Sometimes the user just wants to move the mouse of the remotely controlled machine, but not any action, then this check box is optional, any action on the screen image of the current controller will be sent to the screen. Control the machine, not the click or double click operation made by the user. XY current mouse position. Send manually sends a mouse button message. The system allows you to set a variety of mouse action information through the mouse control area, and press the Send button to manually send the specified mouse action. Refresh manual refresh screen image. Right part: INPUT Enter text.

CRLF check box: Whether you are in the entered text, add a carriage return. START: Select the execution control command Normal Ssaver Locked indicates the status of the current controlled machine. Normal Login Status SSAVER: The controlled machine is in the screen protection status Locked: The controlled machine is locked or not logged in, how to remotely operate the controlled machine: analog keyboard action, when the remote desktop image is in focus status (mouse in the image area Inside), you can tap the keyboard to send button information, and your local machine. But this is very inconvenient for text for entering the large segment, because your button actions are sent as a HTTP request, and the input speed is very slow. If you want to enter a large section, you can select the INPUT input box, then enter the text you want to send, press Enter, if the CRLF check box is selected, then the text you entered will be automatically added Enter a loan. Note: The input box cannot simulate the remote desktop console command line input, you can only enter information on the remote desktop console by analog keyboard. (RMTSVC2.3.4 has been revised this feature) However, when logging in remote computer, some machines may not enter the login password directly via the input box (I have already played Pack3), and you can only enter the login password through the analog keyboard. Simulate the mouse action, you can directly click on the desktop image through the mouse, the system will automatically identify your mouse click, double-click, and the left right click information. If you press SHIF, ALT, CTRL keys while pressing the mouse, the system can automatically identify. If you just want to move your mouse to a location, you can select the Only Move check box so that any mouse action on your desktop image is only translated into a mouse mobile action 2, refresh desktop images, each mouse / keyboard / Image Quality Settings The action automatically refreshes a remote desktop image, you can also click the Refresh button to manually refresh the desktop image. When the Refresh button becomes gray indicates that the desktop image data is receiving. Sometimes you have sent it, because the screen capture is earlier than your action, the remote desktop on the browser may have no change (the received image has been received), you can click the Refresh button to manually refresh desktop images again. . Of course, in order to more conveniently control the remote desktop, you'd better set the remote desktop image to automatic refresh, so there is no action to send out the image without changes in manual refresh. Set the remote desktop automatic refresh, select the auto-refresh item in the Start drop-down list box, pop up a input box that allows you to set up automatic refresh intervals, you can enter the minimum refresh interval (milliseconds), and cancel automatically refresh. The refresh interval is 300 ms, less than 300ms refreshed with a desktop image at 300 ms. 3. Control Command: The Start drop-down list box is the currently supported control command. Ctrl Shift Del Simulation Send Ctrl Shift Del Button Shutdown Remote Shutdown Restart Restarting Machine LOGOFF Remote Logout System Current login User LOCK Lock Current Computer Lock MS & KB Lock Remote Computer Keyboard and Mouse Display Remote Corrupted Machine Crystal Mine The password in the middle. Select the Password-> Text item of the Start drop-down list box, this will change to text-> password. At this point, as long as your mouse left click on the password input box of the remote desktop image, the password in the remote control machine password box is translated into a clear text display.

If you cancel this feature, click the Text-> Password item, this time this will change to password-> text. Remote executive, select the Run ... item of the Start drop-down list box, you can enter the file name and parameters you want to perform remotely, using the method of running the command with the Windows Start menu. Analog F1 ~ F12 button 5. Proxy proxy service start / stop Proxy service. Set the port of the Proxy service, the default is 8080 to set the permissions to access the Proxy service, whether you allow anonymous access, if you do not allow the username password to access the access. Set the proxy protocol that this agent service allows support, the default supports HTTPS, SOCKS4, SOCKS5 (Note this SOCKS5 does not support UDP proxy) Set whether to connect the second-level agent, if you have to connect the agent, if there is a secondary agent, then The above access username and password should be filled in the username and password required by this agent to access the secondary agents. Setting a proxy access rule, the default access rule is whether all users who do not meet the set access rules criteria are allowed / forbidden to use the agent. Setting of access rules: Enter [Type] sp [netmask] sp [dest p] sp [netmask] sp [dest ip] c [dest port] sp [deabled] CRLF TYPE - Protocol Type 0-All 1-TCP 2-UDP NetMask - Network mask. For example: 255.255.0.0 DEST IP - Access destination IP address, Example: 172.18.0.0 dest port - Accessed destination port, if set to 0, ignore this condition enabled - is allowed to meet the above conditions Access users use this proxy service 0: Prohibited 1: Allow, for example: 1 255.0 80.0 172.18.0.0 80 1 0 255.255.0 80 192.168.1.0 0 0 indicates that any IP and network mask 255.255.0.0 are equal to 172.18.0.0 The proxy requests based on TCP access and accessing destination ports are 80 are allowed. Any IP and a network mask 255.255.255.0 correspond to a proxy request for 192.168.1.0 prohibited. 6. FTP service start / stop FTP service. Set the port of the FTP service, the default is that 2121 sets the permissions to access the FTP service, whether anonymous access is allowed, if not allowed, the username password is set. Allows the accounts for different access, each account can specify whether to write / delete / executable and set different FTP root directory users can enter multiple access account information in the text input box, each account information is separated by carriage return The account information format is as follows: [user] sp [password] sp [permission] sp [root path] CRLF user - account name password - password permission - Access permission 1: Can write 3: Write and can be deleted 7: writable Delete the executable root path - Allow this account to access the directory, including the subdirectory of this directory. That is, the root directory of the FTP account is not allowed to access other directory other than the root directory Note: FTP account information is only written to the registry to save, and it will not be saved to Exe itself. 7. Telnet service start / stop Telnet service. Set the port of the Telnet service, the default is that 2323 sets the permissions to access the Telnet service, whether you are allowed to access, if you do not allow the username password to which you are accessible. 8. VIDC service VIDC is not really providing space, but you can build your own web service (website) or other TCP services on top.

You have built your own homepage, but there is no public page of the public network? Do you want to access / control your own machine in your company? How to do? Use virtual IDC! It allows you to map the services in the LAN to the Internet so you can access the services in your LAN in anywhere. VIDC includes two parts: VIDCs and VIDCC. The virtual IDC client is responsible for maping a service in the specified LAN to a port of the virtual IDC service. When a user accesses the virtual IDC service The specified port of the machine, the virtual IDC service access request forwards to the virtual IDC customer, and then the virtual IDC client connection is really bound to the user while returning the response to the user. RMTSVC2.4.5 itself is a VIDCS service. The port of the service is also the server port of the RMTSVC. At the same time, the RMTSVC also has a VIDCC client function. You can connect other RMTSVC services through the RMTSVC VIDCC function and map the specified TCP service port to other RMTSVC The service running machine. VIDC Service Status: Displays the current VIDCS running status, as well as the current map port information. Anonymous Access: Whether to allow anonymous access to the VIDCS service, if the VIDCC client must enter a password to connect to the port. The VIDCS server verification password is the access password for the RMTSVC service. Vidc Client Status: VIDCC Run State. Specifies the VIDCS IP port to connect to connect to VIDCs, map the port on the VIDCS of this RMTSVC. If specified as == 0, the map port is consistent with the port of this RMTSVC. If <0 does not reflect the RMTSVC service, just connect VIDCs. If VIDCS does not support anonymous access (ie, the required verification), you should also enter the access password for VIDCS (ie the access password of RMTSVC2.4.5). The port of the Map RMTSVC is set to the destination port you want to map, that is, the port you want to access through the VIDCS service, set this port to note that the port you set on the machine is not occupied! ! ! . If it is set to 0, the mapped destination port is consistent with the mapped port (if <0 does not reflect the RMTSVC service, just connect the VIDCS), for example, the port of the RMTSVC you want to map is 7778, if the Map RMTSVC is set to 0 The port is mapped to the VIDCS service. (Note that this port on the destination machine is not occupied, otherwise the connection is unsuccessful !!!) Connect to VIDCS, you can add / remove other mapping ports. Nine, Option Parameter Set MODIFY Password: Setting RMTSVC Access Password Service Port: Setting the RMTSVC Service Port (take effect when restarting the RMTSVC), pay attention to if set to 0, select the service port. Start Control: If you don't install the RMTSVC as a Windows service, this option will appear, select the RMTSVC automatically installed the RMTSVC to Windows service, so that the RMTSVC service will be automatically started after each startup. Stolen Mode: Hide RMTSVC Services Start Mode: Set whether or not the following service 1, FTP service 2, Telnet service 3, Proxy service 4 is automatically connected after RMTSVC run, whether the RMTSVC service port is automatically connected to the specified VIDCS server.

5, if the RMTSVC is running, it releases the DLL. If the release is released, the DLL name is released, the default is released, the name is INJECT.DLL. In order to prevent automatically released DLLs from being killed by anti-virus software, users can choose not release DLL. Manually copy the plus-shell DLL to the system directory of the controlled machine, fill in the DLL name after the DLL is released at the name of the DLL. The DLL released by RMTSVC is mainly used: hidden process, analog Ctrl Alt Del button, display the password box password, monitor the RMTSVC run an exception, automatically restart if the abnormality exits or kills, write the configuration parameters to the RMTSVC program itself . Killed Program: Sets the RMTSVC monitor and automatically kills the process name, and each name is separated by a comma. Login Users: Displays user information that is currently logged in and accesses this RMTSVC service. Function Button: Save: Save RMTSVC Current Configuration. There are two options: Save the configuration parameters to the registry or save to the executable itself. If saved to the executable itself, the RMTSVC service will restart. (Note Only if you can write the configuration parameters in the hidden mode, you can write the configuration parameters to the EXE itself if you do not save normal exit in RMTSVC.) STOP: End the RMTSVC program. (If you are in hidden run mode, you will automatically write the configuration parameters to the registry and executable itself before the end. (Re-running RMTSVC starts with new service ports set) Ten, HTTP mode file management RMTSVC2.4.6 supports file management of HTTP mode, as long as copying the WebE directory in the compressed package to the directory where the RMTSVC is located, if You don't want this feature to delete the WebE directory. If you have a webe directory, there will be a Files menu on the RMTSVC's management interface. Click Go to enter a similar resource management page. Currently support upload / download, double-click operation, property modification, file name modification, create a directory, File Preview (Preview GIF / JPEG, DOC documentation, and any displayable plain text files), file searches. The operational method is basically similar to the resource manager, but the drag operation is not supported. 1. File search In the file search box Enter the file name to search (support *? Wildcard, if you search each file, each search keyword is divided by a comma), then click Search, the search directory is always open. Directory and its subdirectories. 2. File download / run double-click the file name, you will be prompted to download the file or run the far end. If you double-click a directory, you will open this directory, display the file directory list 3, modify the file name Click to select the file, then click the file again, you can display a input box. Enter the Enter the return to 4, display the modified file. Directory Properties Click Select the file / directory, press the property button in the toolbar, or select the properties menu of the right-click menu 5. File operation support Ctrl, Shift check, support Ctrl C, Ctrl X, Ctrl P operating. 6. File Preview If you want to preview the contents of the file, you can press the preview button in the toolbar, you can display a preview box, any previewable file, will be displayed in the preview box, previewed files include (GIF / JPEG , DOC, HTML, and any plain text file, the system can automatically identify those plain text files that can be displayed).

If you don't want to preview the preview button again, you can 7, the file upload toolbar The left button is the file upload button, the default upload directory is the current open directory 8 ... >> Download << CopyRight © 1998-2003

转载请注明原文地址:https://www.9cbs.com/read-124658.html

New Post(0)