8-9-04, Xi'an Expressway Construction Corporation Network fault.

xiaoxiao2021-03-06  205

??????? Today, I went to the high-speed group, the weather was really hot, and it was very bored. Really sin. I thought that the computer room had air conditioning, it's right, it really had air conditioning. But there is no refrigerant, and it is not the same. It is necessary to die. Network topology:

?????????????????? Company ---- protocol converter-photoelectric converter ----------- 2MB fiber ----- ----- Photoelectric Converter ---------- Protocol Converter ------- Branch.

On both sides, the time is intermitted. There is no problem with the fiber. Take a look at the configuration on the core 4006 is correct. Finally, I decided to change the protocol converter and change at the same time. As a result, I changed the head office, then I came to the branch, normally. The problem is on the converter. Then go to the branch to configure Valn 34, and the result is not formulated on the switch, and the PING will not be 4006. Decided to configure the switch, VLAN 1 VLAN 34,

VLAN 1's address configuration 192.168.100.101, VLAN 34 0/2 - 24 can be communicated after configuration. details as follows:

EN

Conf t

INT FA 0/1

Switchport Trunk ALLOW ALL

Switchport Access VLAN 34

Int VLAN 1

IP ADD 192.168.100.101 255.255.255.0

NO SH

INT RANGE FA 0/2 - 24

Switchport Access VLAN 34

The configuration ends.