two. Performance test script automatically establishes DataPool
In Robot Tools-> Session Record Options, set the generator page General's Use DataPool option to generate DataPool.
General recording performance test scripts, follow these steps:
the first. Set recording session option
second. Start recording dialogue
third. Start the client program
fourth. Have a script
fifth. Close client program
sixth. Stop recording
Setting Options:
1. Recording method: API, NetWork, Proxy, Custom 4 option settings
By analyzing the software architecture to be tested to select the recording method, the table below provides a reference:
Situation
API
NetWork
Proxy
The Client Application Access Secure Data from A Web Server
Required
The Client Application Access Data from A Web Server
Recommended
Fist alternate
SECOND Alternate
The Client Application Accesses Objects ON A DCOM Server
Required
The Client Application Access An Oracle8 Database or ORACLE Arrays.
Required
The Client Application Access An Oracle Database (for Network and Proxy Recording, Supply the name of the oracle database,)
Recommended
First Alternate
SECOND Alternate
The Client Application IS Not Installed on The Local Computer
Recommended
Alternate
The Client Application IS Not Running On Windows NT4, Windows XP, or Windows 2000
Recommended
Alternate
You want to record traffic from Multiple Client Applications That Reside On Different Commputers
Recommended
Alternate
You want to record traffic BetWeen Multiple, Specific Clent and Server Computes.
Recommended
Neither The Client Nor The Seri Computer Is On Same Network Segment As The Local Computer
Required
An Ethernet Controls Network Traffic, And Neither The Client Nor The Server Application IS Installed on The Computer
Required
The Client Application Accesses A Tuxedo Server
Recommended
Alternate
"On-the-Wire" Recording Support is laconing
Recommendedalternate
API Recording Is Not Functioning Properly
Recommended
Alternate
FDDI, ATM, or Other Hight-Speed Networks Are Used
Recommended
Note: Reference Rational Robot User's Guide,
The NetWork recording must be installed in Rational network driver to take effect.
installation method:
1. Start -> Settings -> Networks and Dial-up Connections
2. Point local connection
3. Point installation, select protocol, point addition
4. Click to install from disk
5. Open the installation directory c: / program files / russional / rate test / driverw2k (Install Rational Directory), selector INF file, determine
6. Select Ethernet or token Ring
2.Generator Filtering
FILTERING
(1). Setting Autofiltering to automatically select the available protocol when the Robot generates scripts, and the list of protocol gatherings available
Special explanation of DCOM is an exclusive agreement that cannot be coexist with other agreements.
If the background is SQL Server, select SQLServer, if the background is Oracle, select the Oracle protocol. Select different protocols according to software implementation.
(2). Set the manual protocol filtering to make the Robot generated script
3.Generator per protocol
Only part of the partial protocol (HTTP, IIOP, ORACLE, TUXEDO, and DCOM) selected in Generator Filtering.