SDE CAD Client's Introduction

xiaoxiao2021-03-06  40

CAD Client provides AutoCAD to read and write SDE graphics data. However, when the graphic drawing in AutoCAD is stored in SDE through the CAD Client, the case where the warehouse has not been enabled, and it has been discovered as the following question:

1. Drawn self cross. In fact, most of the errors are caused by graphics. The self-crossing PLINE line cannot be parsed in SDE, so it cannot be enabled. For closed PLINE lines, you can check if you can create a parallel problem. Often some somewhere where the naked eye can be seen, such as the day before yesterday, it is a problem with a circular arc and a straight line. . .

2. The PLINE line is enabled for line-style generation. I don't know why, the line style generates this property must be disabled.

3. The end of the closed PLINE line is a circular arc. SDE does not support this structure, although it can be enabled, the graphic after the storage is problematic - the arc becomes a straight line. The solution is to add a point to cause the starting point and the end.

There may be other problems, but this is currently mainly discovered.