Copyright Notice: This article can be reproduced, please be sure to indicate the original source and author information in hyperlink when reprint. Original source: http://www.aiview.com/hobbies/ham/kenwood_th48_manual.htm Translator: Zhang Yang Alex_DoESATMAIL.COM, BG1OLZ Reference: English Manual Scan, Picture Format, Non-text electronic file, if necessary Send an email. Last updated: 2002-4-9
table of Contents
The Chinese Operation Manual of the Kenwood TH48 is also suitable for TH48Q and the V-block TH28 of Jianwu. Some functional operations of the Jianwu series hand are common, and other models can also refer to this manual as appropriate.
Some of the translators:
The author's first translation of this professional profile, although the school is changed, it will inevitably have errors, if you find, especially technical, please contact me to help the survey, thank you!
The transmitting and receiving part of the dual-tone static noise system and short message has been translated, so they directly refer to the original text of the golden monkey [ID ON green field], one is placed here.
Some terms explained: Sub band - If the TH-28 machine, the sub-band is 100MHz segment; if it is a TH-48 machine, the sub-band is 400MHz segment. When reading, pay attention, some examples are For TH-28.
Main band (Main Band) - Explains the opposite of the Subpass in the above.
PTT key - That is, the transmit button.
VFO mode - the frequency mode.
===================== Directory =====================
Annex 5
Pre-use 5
Illustration 6
Battery
1. Nickel-cadmium battery pack (PB-13) 8
2. Charging 8
3. Install the battery pack 8
4. Battery voltage standard 9
5. Battery use time 9
Receive operation
1. Start using 10
2. Select frequency 11
3. Selection of step frequency sizes 12
4. Programmable VFO adjustment limited 14
5. Sub-band reception 14
Launch operation
How to launch 15
2. Change the transmit power 15
3. Turn off the launch (TX) function 16
4. Timed operation 16
Use memory
1. Data backup 17
2. Enter the storage data 17
3. Initialization Memory 18
4. Storage channel 18
5. Storage content 18
6. Enter the difference rate 19
7. Enter Call (CALL) frequency 19
8. Tune the stored channel 20
9. Turn the frequency in the channel to the VFO mode 20
10. Display of characters in the channel 21
scanning
1. Abort / recovery scan 22
2. Scan option 22
3. Scan the stored channel 23
4. Lock the stored channel 23
5. Bode Scan 24
6. Programmable band scan 24
7. Frequency scan 26
8.VFO / channel alternating scan 26
9.call/vfo alternate scan 26
10.call/ Channel Alternation Scan 26
11.V / m / c (VFO / channel / call) alternate scan 26
Relay operation
1. Differential transmission 27
2. Select the difference frequency direction 27
3. Automatic difference rate 27
4. Manual difference 28
5. Upside down reception and emission frequency 28
6. Tone operation 297. Call forwarding 30
8.DTMF Storage 31
9.CTCSS operation 33
Dual audio static noise system (DTSS)
1.DTSS encoding 34
2. Use DTSS 34
3. Use DTSS 35 through relay
Short message transmission and reception
Message Send Mode 42
2. Storage message 44
3. Check the stored message 44
4. Send a store 44
5. Receive message 44
6. Receive the storage 45
Extra function
Audio warning system 46
2. Received 47
3. Turn off the beep 47
4. Backlight 47
5. Keyboard lock 47
6. Simple Channel Display 47
Power saving function
1. Power-saving mode 48
2. Automatically turn off the power (APO) 48
Clock function
1. Clock setting 49
2. Timing switch 49
Switch band operation 51
maintenance
General information 52
2. Services 52
3. Resume 52
Maintenance 53
annex
1. Install CTCSS unit (TSU-7) 55
2. Memory expansion unit (ME-1) 56
3. Programming SMC-33 Remote Control Speaker and Microphone 57
4. Use other microphones 59
5. Connect the external speaker 59
Specifications 60
Reference 61
==================== 正 =========================
【annex】
Antenna (TH-28A / 28E)
Antenna (TH-48A / 48E)
Strap hook
Wristband
Rubber hat
AC plug (normal type only)
Nickel-cadmium battery pack (PB-13)
Battery charger (BC-14)
US and Canada 120V
Europe 220V
United Kingdom 240V
Ocean 240V
Other markets 120 / 240V
manual
Warranty card (USA, Canada, Europe)
【Battery】
Nickel-cadmium battery pack (PB-13)
The battery must be charged before use. The battery does not reach the best cycle charge when you order the factory. It is necessary to circulate and discharge it before reaching maximum discharge performance. If you idle the battery for more than two months, you need to recharge before use.
2. Repeat charging
Insert the charger (BC-14) plug into the socket top of the machine, and then connect the charger to the AC power. Do not allow charging for more than 15 hours, if you exceed the recommended charging time, it will affect the battery life and performance.
3. Install the battery pack
Insert the battery pack into the machine until it is locked. Sliding the release button to the right can remove the battery pack.
4. Battery voltage level
This meter indicates the amount of power during battery emission.
The battery needs to be charged or replaced when the level reaches the low electricity instruction.
Manganese or alkaline battery
In the battery case (BT-8), a 6-section 5 helicanese or alkaline battery is applied, and it is recommended to use high energy alkaline batteries.
5. Battery use time
6 seconds, 6 seconds, recommend 48 seconds, no signal
AF output 0.2W / 8 ohm
Open power saving function
When the battery is lowered, the display will flash and the power will be turned off.
For long-term launch or expansion, we recommend using nickel-cadmium battery packs.
Manganese batteries (except alkaline batteries) can only be used when low-grade transmission power.
[Receiving operation]
Start using
Install battery packs and antennas.
Press the power switch to turn on the machine and the default frequency will be displayed on the screen.
If an error or display frequency is displayed, reset the microprocessor (refer to 18 Page Initialization Memory).
1) Rotate the volume control clockwise until the signal or noise is heard. 2) Rotate the FM control button to select an open channel.
3) Clockwise rotate the static noise (SQL) control button until noise disappears and display the lamp "busy"
2. Select frequency
You have several ways to select frequency:
Use the button to enter the specified frequency
Use the FM control
Select a stored channel (reference 20)
Press the call (CALL) button
Keyboard direct input frequency
The following demo uses TH28 how to enter 145.050MHz.
1) If the machine is switched to the VFO mode by the VFO key in channel mode or call mode (Call).
2) Press the numeric keypad to enter the corresponding number.
Use the fax knob
The frequency frequency knob is high or a low continuous step in change frequency, clockwise or counterclockwise rotating the modifier knob to select the desired frequency.
3. Selection of stepping frequency
The selection step inverting frequency must be in VFO mode.
The step frequency size of the selection of FM or scans requires the following steps:
1) Press the F button and press the MHZ / STEP button to display the current step frequency.
2) Rotate the Frequency Coven until the step frequency shows the size you want to set. According to any one button (except for LAMP, MONI, Power), the displayed step frequency has been set.
4. Programmable VFO FM
This unit provides a function of programming the VFO frequency modulation range, providing a separate programmable band scan function in a 1MHz band. (Refer to page 24)
For example: You want the machine to faster only within two frequency bands of 144.000 and 145.000, you can do the following:
1) Rotate the Frequency Direction until the lowest frequency you want to limit, this example is: 144.000MHz.
2) Press the M key and keep it more than 1 second, then press 7 buttons, the lowest frequency has been set.
3) Rotate the Frequency Direction until the highest frequency you want to limit, this example is: 145.000MHz.
4) Press the M key and keep it more than 1 second, then press 4 buttons, the highest frequency is also set.
5) Rotate the Frequency Cath to confirm that the machine does not adjust to the frequency that has been restricted on the upper side.
To clear the two programming limits to reset the VFO memory, refer to 18 pages.
You can rearrange any restricted bands through the appropriate instructions above.
Note: This feature is invalid in sub-band.
5. Sub-band reception
Press the BAND button.
The sub-band frequency will be displayed, you can choose the frequency you want to use in accordance with the second section of this chapter.
[Launch operation]
The antenna needs to be installed before the launch is to check if the frequency is correct.
1. Use the following steps:
1) Use any method to select an operating frequency.
2) Check if this frequency is occupied before transmitting.
3) Press the transmit button (PTT), the ON Air indicator, and the power indication will illuminate.
4) Speaking against the microphone, the recommended distance is 5 cm. It is too close to too much or too far to cause the signal too strong or too weak.
5) Store the PTT button, return to the reception mode, the ON Air indicator and the electric quantity.
2. Change the transmit power
Pressing the LOW button to replace 4 different transmit power. The actual transmit power depends on the remaining power of the power supply, and the indicator displays the currently selected transmit power.
E and L indicators represent low power of the economy when communicating in a short distance, using EL power.
The indicator indicates a low power and a short-range communication uses L power.
M indicator indicates the middle equivalent.
No power indicator indicates the maximum power transmission.
3. Turn off the launch (TX) function
The TX STOP feature allows you to prohibit the machine to transmit, press the F key, then press the low / tx.s key to convert the TX STOP function to open or close. 4. Timed operation
This unit has timeout timer function to prevent accidental problems that may encounter results in continuous emission. This feature is forced to stop transmitting after 10 minutes, and the time set by the timer is exceeded, the machine will be beep and return to the reception mode, and can be transmitted again according to the transmit button again.
This feature does not allow users to open and close operations.
[Use memory]
Data backup
All stored channel data, call channel data, DTSS encoding, message, and finally displayed channels and VFO frequencies are saved in the EEPROM. This data will always be saved unless you reset the memory.
The other data is maintained by the lithium battery in one machine. When the machine does not connect the battery pack or an external DC power supply, the battery can provide a save time for about 20 days.
When this battery is completely discharged, it needs to be charged for 10 hours after you connect a nickel-cadmium battery pack or an external power source to achieve the best use.
2. Enter the storage data
Enter the operation of the stored data is relatively simple, just you need to hold the data you want to store as you can save.
Enter the channel
1) Use the digital buttons to select the frequency, difference frequency, and other information you want to receive. If the frequency you want is already in the frequency you want, continue until 2.
2) Press the M key, the number indicating the channel on the screen will flash.
3) Press the key to enter the channel number (00 ~ 39) you want to set, enter the channel number with two digits, such as 2 channel input 02, 15 channel input 15.
4) Press the MR key.
5) The channel number is no longer flashing, and the displayed frequency has been saved in this channel.
Delete channel
Delete the frequency that has been stored in the channel by following these steps:
1) Select the channel number you want to delete.
2) Press and hold the m key 1 wonderful clock or press the MR key.
3) The selected channel has been removed from the memory.
3. Initialization memory
Turn on the M key while opening the power switch can reset the memory, all LCD indicators displays the red screen and release the M key. This will clear all the user's storage content and restore the factory's factory parameter settings.
Factory parameters
VFO reset
Turn on the power switch to reset the VFO memory of the microprocessor while holding down the F key. This does not affect the stored channel, clock, message, automatic DTMF, programmable scan scan range limit, Paging, or Call (CALL) content.
4. Storage channel
This unit provides 40 channel storage (00 ~ 39), which will provide additional channel storage from 40 to 239 after adding ME-1 (storage extension unit).
5. Store content
The content that can be stored for each channel is as follows.
×: Can store
N / A: Cannot be stored
6. Enter the difference frequency
1) Use the button to enter the received frequency, if this frequency is currently displayed, jump to the second step.
2) Press the M key and the storage indicator m will illuminate.
3) Select the channel number to save.
4) Press the MR key.
5) This frequency is already stored.
6) Use the button to enter the transmit frequency.
7) Press the M key and the storage indicator m will illuminate.
8) Press and hold the transmit button (PTT) while pressing the MR key.
9) The transmit (TX) frequency setting is complete.
Confirm the input difference frequency
1) Press the MR key to select " " and "-" on the screen to indicate that this channel has been set up.
2) Press the F button, press the REV button or the PTT key to check if the transmit frequency displayed in the screen is correct.
7. Enter the frequency of calls (CALL)
1) Use the button to enter the received frequency, tone, and other information. 2) Press the M key, then press the CALL button within 10 seconds, the call frequency is set. If you need to set the difference, continue step 3.
3) Enter the transmit frequency you want to set.
4) Press M key.
5) Press the CALL button while holding down the PTT key.
6) Let the PTT key and set it.
8. Tune the stored channel
Press the MR key, you can change the channel by two ways.
Use digital buttons
Enter the channel number you want to set.
Switch to three storage mode.
If ME-1 is installed, the memory channel exceeding 100 cannot be adjusted under two storage mode (initial mode). You must switch to three mode.
1) Press the F button for more than 1 second, then press the MR key. Cyclic conversion will be performed between 2-bit-3-bit-1 -2 bits. (Translator Note: If ME-1 is not installed, it will be converted between 2 - 1 bits.)
2) Repeat the operation until you set it to the mode you want.
Frequency knob
Clock-clockwise or counterclockwise rotate the modifier knob to select the channel you want.
9. Turn the frequency in the channel into the VFO mode
Press the F button, then press the VFO button to transfer the current frequency in the channel or call channel to the VFO mode, which does not affect the stored data.
The frequency within the proclaimable VFO is not to be transferred to the VFO mode.
Note: When this function is used in the channel provided with the different frequency, only the received frequency is transferred to the VFO mode.
10. Display of characters in the channel
You can enter characters instead of displaying the frequency in the channel, and its length must be set to 6 characters, you can use numbers 0 to 9, letters A to Z and blank.
If this mode is used, channels 00 to 19 will be displayed, and channels 20 to 39 will be occupied and used as storage of character information. If there is frequency data in channels 20 to 39, it is replaced with character information data. (Translator plus: channels 20 ~ 39 will no longer be used because its storage space is occupied by character data)
If you have ME-1 installed, channels 40 to 139 will automatically become channels 20 ~ 119. (Translator Note: Consider should be 40 ~ 239 to 20 ~ 219)
Function settings
1) Press and hold the MR button to press the power switch. (This operation can switch the opening and closing of this mode)
2) Press the MR key to enter channel mode.
3) Select a stored channel.
4) Press the M key and press the MHZ button to enter the message setting mode.
5) Use the button to enter the message, refer to page 43 About the correspondence between the button and the letter.
6) If you enter an error, press the VFO button to start again from step 5.
7) Press the MR key to end.
8) You can display other channels in accordance with step 2-6.
If a message is assigned to a storage channel, this information will replace the original frequency display. If you want to see the frequency of this channel, you can press the F button, then press 5.
Restore channel frequency display
1) Select the channel to cancel the message display.
2) Press and hold the m key for more than 1 second, then press the MHZ button. The message display will be canceled, and the frequency will replace it.
【scanning】
For normal scans, the static noise knob (SQL) must be adjusted to start with the alert function.
Substance / recovery scanning
This unit provides two types of scanning operations:
Cycle Scanning Operation (TIME)
The machine stops when scanning to an occupied channel and keeps approximately 5 seconds and then proceeding to the scan.
The carrier scanning operation stops when scanned to a occupied channel and remains to the signal disappears. In order to prevent the signal of a channel, it will delay in 2 seconds and then enter the next channel scan.
The machine defaults to the cycle scan mode when the machine is shipped, and the following method switches between two modes.
Press the power switch while holding down the 5 key.
Note: 1) In CTCSS operation, the scan is stopped only when scanned to the matching CTCSS encoding.
2) In DTSS operation, as long as a signal is received, he stops scanning (the static noise function cannot be opened), and the slefit function can be opened in any case when scanning to a DTSS signal, no matter where it is necessary, etc.
3) When the CTCSS and DTSS are opened at the same time, the scan is stopped after receiving a suitable CTCSS signal. When the scan is stopped, if the DTSS signal has been received, the static noise function can be opened.
2. Scan option
3. Scan the stored channel
Note: This machine can only scan the stored frequency and is not locked, and there must be 2 or more channels already store frequencies.
1) Adjust the static noise knob to the starting position.
2) Press the MR key to switch to channel mode.
3) Press and hold the MR key for more than one second. When the scan begins, the decimal bits of the frequency indication will flash.
4) Press the PTT button to stop the scan.
4. Lock the stored channel
This feature allows you to specify that you want to give up the scanned channel in the channel scan.
1) Select the channel you don't want to scan.
2) Press the F button and press 6 / L.out key.
A star indicator shows the lower part of the channel number, indicating that this channel is skipped when channel scan.
3) Repeat the first and second steps to lock any other channels to give up.
4) Want to cancel the lock of this channel, choose this channel, and can cancel the second step.
5. Band scan
1) Adjust the static noise knob to the starting position.
2) Press the MR key to switch to the VFO mode
3) Press and hold the MR button for more than one second, start scanning by low frequency to high frequency, and the decimal bits of the frequency indication will flash.
4) When scanning a stronger signal, the scan is paused, the BUSY indicator is on.
5) Press the PTT button to stop the scan.
6. Programmable band scan
This machine can edit two scan bands. Scan upper and lower limit frequencies can be limited to each band.
Edit Scan Wave Segment 1
1) Rotate the FM control knob and select the scan upper limit frequency.
2) Press the M key for more than 1 second, then press 5.
3) Rotate the FM control knob and select the scan lower limit frequency.
4) Press the m key for more than 1 second, then press 8.
Edit scan band 2
1) Rotate the FM control knob and select the scan upper limit frequency.
2) Press the m key for more than 1 second, then press 6.
3) Rotate the FM control knob and select the scan lower limit frequency.
4) Press the M key for more than 1 second, then press 9.
Confirm scan restrictions
Band 1 scan upper limit frequency
Press the F button for more than 1 second, then press 5.
Band 1 scan upper limit frequency
Press the F button for more than 1 second, then press 8.
Band 2 scan upper limit frequency
Press the F button for more than 1 second, then press 6.
Band 2 scan upper limit frequency
Press the F button for more than 1 second, then press 9.
Start programmable band scanning
1) Adjust the static noise knob to the start position
2) Select a frequency between these two restrictions.
3) Press the VFO button for more than 1 second.
4) Scan start.
5) Stop scanning by PTT.
7. MHz scan
1) Adjust the static noise knob to the starting position.
2) Start the band scan and programmable band scan.
3) Press the MHZ key during the scan, the scan will be scanned within the current 1MHz. For example, when the frequency is 145.02 MHz, you press the MHZ button, then the next scan will be repeated in the 145MHz band.
8.VFO / channel alternating scan
1) Press the F button and press the MR key.
2) The machine will be scanned between the last VFO frequencies and the last use channels.
3) Press PTT to abort the scan.
9.call/vfo alternate scan
1) In VFO mode, hold down the CALL button for more than 1 second.
2) Alternately scan between two frequencies of VFO and CALL.
10.call/ channel alternating scan
1) In channel mode, hold down the Call button for more than 1 second.
2) Alternately scan between two frequencies of channels and CALLs.
11.V / m / c (VFO / channel / Call) alternate scan
1) Press the F button and press the CALL button.
2) The three frequencies of VFO, channel, and CALL will be alternately scanned.
[Relay operation]
Different frequency launch
All amateur radio stages use separate reception frequencies and emission frequencies, and the accepted frequency can be higher than the emission frequency or less than the transmit frequency. Most tricks' differences use one of the following categories.
2. Select the difference direction direction
Press the SHIFT key, the machine will switch the direction of the difference, such as switching from , or from-switching to the different frequency, no symbols when there is no difference frequency.
In the European version of the machine, in the UHF band, - displayed.
3. Automatic difference frequency
USA and Canada version
The TH-28A has set a difference in Amateur Radio Relay League based on the trunk, you can also refer to the paragraphs described above with the Shift key yourself.
European version
TH-28E automatically sets the following difference.
Cancel automatic difference frequency
Press the power switch while holding down the Call key.
This operation is switched between open and closing the automatic difference frequency.
4. Manual difference frequency
The machine sets the default difference value when the machine is shipped, and you can select your own difference frequency value between 0 ~ 99.9MHz.
1) Press and hold the VFO button and turn on the power switch.
2) Press the F button for more than 1 second, then press the 0 button. The current difference value will be displayed.
3) Rotate the Frequency Coven knob and select the difference frequency you want to set.
4) Press any panel button to return to normal display mode.
If you want to recover the standard difference, reset the VFO (refer to 18 pages)
5. Upside down reception and emission frequency
Some tricks use the received and transmit frequencies that are reversed with other tricks.
Such as: The reception frequency of the relay station A is 146.000, the transmit frequency is 146.600; the accepted frequency of the relay station B is 146.600, which is 140.000, so that when you want to use this relay, you will be reset when you want to use this relay. The opposite difference frequency. It can be easily upside down the difference with the following operations to achieve the effect of fast switching between two interrupts.
Press the F button, press the Shift / Rev button, an indicator R is displayed on the screen, indicating that your current difference is reversed.
Press the F button, then press the Shift / REV button to return to the normal state, the indicator R is off.
6. Tone operation
Some tricks need a control signal to be activated.
In the United States, use low frequency tones.
In Europe and the United Kingdom, use a 1750HZ tone transmit signal, just press and hold the TONE key to send, do not need to press the PTT key.
Set tone frequency
1) Press the F button, press the TONE button, the screen will display the current tone frequency.
2) Rotate the Frequency knob and select the tone frequency you want to set. 3) Press the TONE button again or wait for 10 seconds, set up.
Send tone
Press the TONE button, a T indicator is on, and press the PTT button to send you the tone you set.
7. Call forwarding (AutoPatch Operations)
(This feature is only available)
Some relay provides call forwarding capabilities, allowing you to use the transceiver to call a phone number and communicate.
This feature needs to use the DTMF (Dual Tone Multi Frequency "keypad, more four keys than 12 keys: A, B, C, D.
These keys are used to make some different control operations on some relay systems, which show these keys to generate correspondence between different audio.
Activate DTMF keypad:
While holding down the PTT key, call the phone number on the keyboard like a normal phone.
Note: Some relays need a specified key sequence to activate forwarding function, contacting the relay operator to get this sequence code.
If you press the VFO button before pressing the number key, you will empty a mono, you can hear (see the top left on the left).
Select delay time
If you don't want to press and hold the PTT key while dialing the phone number, you can do the following:
1) Turn off the power switch.
2) Turn on the power switch while holding down the 3 key.
So you can press the PTT key to do not put it, then release the PTT key after the first number of the phone number, then enter the remaining number, as long as the input interval is within 2 seconds.
Repeat steps 1, 2 Turn off the delay.
8.DTMF Storage
You can store 10 DTMF phone numbers that are not more than 15 numbers in the machine.
Store DTMF encoding
1) Press the M key and press the BAND key to switch to the DTMF encoded input mode.
2) Use the button to enter DTMF coding. Example: Enter 123.
3) Press the MR button after the input is complete.
4) Select a channel you want to store within 0 ~ 9.
5) If the error number, press the VFO button to re-enter the first step.
6) Want to exit during the input, press the PTT key, and the information entered will not be saved.
Tune the stored DTMF encoding in the reception mode
1) Press and hold the F button and keep it more than 1 second, then press the BAND button.
2) Press a numeric key (0 ~ 9), and the corresponding DTMF number saved will be displayed.
Perform DTMF call
1) Press the BAND button while holding down the PTT key.
2) Press a number of numbers corresponding to the channel you store the DTMF number.
3) The DTMF number is displayed.
Note: The transmission will continue until the entire number string is sent, once the above operation is performed, you cannot stop the DTMF number.
9.CTCSS operation
Continuous Tone Code Squelch System --- Continuous Audio Code Staic Sick System (CTCSS)
CTCSS unit (TSU-7) is only available in the US and Canadian version, please refer to page 55 for the installation of the chip.
If you open the CTCSS function, the machine will turn off the audio system until it receives a matching audio signal.
Please refer to page 29 for this audio frequency.
Open the CTCSS as follows:
Press the F button, then press the 3 button, a CTCSS indicator lights up.
The audio system will filter out any signal unless it contains an audio signal that matches the CTCSS encoding with the unit.
[Dual Solder Surveying System (DTSS)] (This section is translated by golden monkey, direct reference) DTSS = Dual Tone Squelch System Dual Sikuokable System
When you are in the static noise state, only the information code you set (a three-digit code) is activated in the transceiver, and you can activate the static noise function;
Once the static noise function is activated, it will continue, if there is no signal reception for 2 seconds, it will turn off the scent function until the information containing the information code is received again;
1, DTSS information code:
In the VFO state you can select the 000-999 DTSS information code, consisting of three digits
2, the selection of information code:
Continue to hold the F button for 1 second, then press 2.
Input three digits
3, open the DTSS static noise function:
A, rotating odokinols SQL to 0;
b, press the F button, press 2 buttons, the DT word will appear on the screen;
C. When receiving the correct information code, the static noise will be activated;
d, transmit, press the PTT transmit button, the displayed information code will be transmitted within 0.5 seconds;
Note: When transmitting a DTSS information code, it is in the quiet state, we recommend that you will be able to cancel the power saving function when turning on the DTSS function;
e, press the F button, then press 2 buttons, cancel the DTSS function;
Note: Although you can set DTSS and CTCSS functions at the same wave, it is sometimes lost;
4, use DTSS through relay
Press the PTT to transmit the DTSS information code, there will be a little delay, this delay is to avoid malfunction (the delay of the delay generated during the relay information is the effect of DTSS information code transmission)
The normal delay time is fixed to 259 milliseconds, when the frequency conversion operation is performed, the delay time is 450 milliseconds;
You can also change the delay time to 250 milliseconds:
a, turn off the power switch;
B. Press and hold the 2 button and turn on the power switch;
C, loosen the 2 button; it is OK.
5, DTSS group
You can make a call, packet; See the DTMF network after detail.
[Short message transmission and reception] (this part is made from golden monkeys [id on
Www.lvye.org] translation, direct reference)
-------------------------------------------------- -------------------------------------------------- -------------------------------------------------- --------------------------------
Transceive short messages with a hand (some translations may not be allowed, please enlighten!)
This feature allows you to send a short message to those receivers that have DTMF (dual-tone multi-frequency) functions, and the information content can include numbers 0-9, letters A-Z, and spaces.
Each information is transmitted or the receiving length cannot exceed 6 characters.
Note: This feature is only applied to a hand with a DTSS / PAGING function (DTSS & Message Paging System) is displayed below the native LCD.
1, information transmission mode
Two modes
A. Input directly in the DTMF panel, you must press # to confirm at the beginning and end, and the symbols corresponding to each letter are observed.
b, store information in memory, then send
2, use information memory
The transceiver can store 10 information
Memory stored procedure:
a, press the m key, then press the Message button to enter the information setting status
b, use the DTMF key to enter the information, the character corresponds to the table.
c, if input is incorrect, press VFO button, repeat step 2
D, finally press MR key, the MSG word will start flashing.
3, character correspondence table
0-9 0-9 corresponding to the keyboard
Q correspond to 1 A (f)
A. . . . . . 2 a (f)
Di
G
J
M
P
T
W ......... 9 A (f)
Z corresponds to 1 b (m)
B
E
Hide
K
N
R
U
X. . . . Corresponding to 9 b (m)
Space (Space) corresponding to 1 C (MHz)
C
Fly
I
L
O
S
V
Y ... corresponding to 9 c (MHz)
Example:
C a L M e
2 C 2 A 5 C 5 C 6 A 3 B
Note: The letters need to press 2 keys than the numeric keys, such as c, press 2 buttons, press C
Press a numeric key (0-9) corresponding to the memory channel you want to store
If you want to cancel the information input mode, press the PTT key
4, check information storage
a, press and hold the F button (more than 1 second), press the Message button
b, press a sense of keys (0-9)
c, I want to go back to the normal frequency display status, ordering any key outside 0-9 exits
5, memory information transmission
a, press the PTT button, press the Message button, the MSG word will appear on the liquid crystal panel
b, press the PTT key, press the definition key (0-9)
Note: Even if you release the PTT key, information will be sent continuously even if you release the PTT key.
c, you can repeat the first step and second step, any number of times; therefore, you can use 10 memory channels to continue the text byte by 60 bytes.
6, information reception
A. When the DTSS or PAGING function is on, press the F button, then press the Message button;
B, the MSG display light is on, then you can receive information.
Note: When the new message arrives, it will display, and the MSG display flicker;
7, receive memory information
The transceiver also has 10 message memory storage channels. If you press the Message button, the message is in the message, the last stored information will be displayed;
If the memory is full, the new information will be stored in channel 0.
8, clear the receiving information in the memory
Press and hold the m key for more than 1 second, then press the Message button.
Note: This action cannot clear the information you store to send.
-------------------------------------------------- -------------------------------------------------- -------------------------------------------------- --------------------------------
[Additional function]
Audio warning system
In the audio warning state, when someone is in progress on this frequency, it will send a warning to remind you.
If you set a audio alert, you can't hear it. If the CTCSS is also open, the role of synthesis is similar to a private paging system.
The automatic shutdown (APO) function is blocked during the audio warning work.
Open the audio warning system:
1) Adjust the static noise knob (SQL) to the start. 2) Select a suitable tone, if you plan to use the CTCSS function, check if the CT indicator lights up.
3) Press the F button, then press the 0 key, the indicator light T.ALT lights up.
4) When this frequency is received, it is approximately every 5 seconds, and the indicator light T.alt and Busy will lit and accompany the beep.
5) While receiving the signal, the current time will also be displayed, each time you receive a new signal, this time is followed.
6) Press the PTT key to close the audio warning.
7) Press the F button, then press the 0 button to completely close the warning function.
Note: In order to make the audio warning function can work well in the case of CTCSS, the alarm must last for about 1 second to the received signal. This feature can also be used with the DTSS or paging (PAGING) function, at this time, the alert will occur only when the matching encoding is received.
Select the tone of the alert
Pressing the TONE button (European and British version of the machine to turn on the power switch while pressing the LAMP button), the alarm tone will become a tone similar to the telephone ringtone, repeating this step switching.
2. Received
If you want to be properly recedmed in the case of odor noise (SQL), DTSS, CTCSS or PAGING, you can press the MONI button. After press, the above features do not work.
3. Turn off the beep
Shutdown, then press the 8 key to turn on the power switch, you can turn off the beep when the front panel button is pressed.
4. Backlights
At any time, you press the LAMP button, the backlight of the display will light up, automatically extinguish after a few seconds, if it is too bright, press the following.
1) Press the F button, press the LAMP button, the backlight is always lit.
2) Press the LAMP button again and the backlight is off.
5. Keyboard lock
The lock button on the left side of the slider to the locked position.
One indicates that the lock indicator is lit. In addition to the LAMP, MONI, the PTT three keys, other buttons are locked to prevent errors.
6. Simple channel display
This machine can replace the frequency display of the stored channel with a concise channel number, but must have frequency points already in the channel. CH 1 corresponds to the stored channel 01, CH 2, corresponding to the stored channel 02, and so on.
Switch to the introduction channel display mode as follows.
1) Turn off the power switch.
2) Turn on the power switch while holding down the 1 button.
3) Switching to the introduction mode, you can change the current channel with the button or the FM knob.
4) Repeat 1, 2 to return to standard display mode.
[Power saving function]
Power saving mode
This unit provides a power saving mode to save power, when the machine does not operate after 10 seconds, the node circuit will start. This feature requires static noise to be opened, and once any key is pressed or the static noise is turned off, the node circuit is turned off.
The node circuit does not work during the opening of the scan function and the audio warning function.
Set up power level
You can change the role of power saving function.
1) Press and hold the F button and keep it more than 1 second or more.
2) Select the appropriate ratio between 1: 1 to 1: 16 using the frequency knob.
3) Press any key to return and set it.
2. Automatically turn off the power (APO)
1) If there is no operation within 59 minutes, and the currently no signal is received, it will be called 5 seconds.
2) The machine power will automatically turn off within 1 minute after the call is completed.
Note: Even if this feature is opened, it will not work during the operation of the scan function and the audio warning function.
3) Press the F button, then press the 8 key to turn this feature. [Clock function]
When the machine is in the reception mode, press the F button, then press 9. You can display the current clock and use a 24-hour system. Repeat the above operation to restore normal frequencies.
1. Clock setting
1) In the clock display mode, press the F button, then press 1 button.
2) Rotate the Frequency Direction to set the hour portion.
3) Press the M key.
4) Rotate the Frequency Coven knob to set the minute portion.
5) Press M-key to store exit.
2. Timed switch machine
Timed boot function
1) In the clock display mode, press the F button, then press 4. Enter timing boot time setting status, indicator Timer.on and time's HOUR section start flashing.
2) Rotate the Frequency Direction to set the hour portion.
3) Press the M key.
4) Rotate the Frequency Coven knob to set the minute portion.
5) Press M-key to store exit.
Timed shutdown function
1) In the clock display mode, press the F button, then press 4. Enter timing shutdown time setting status, indicator Timer.off and time's HOUR section start flashing.
2) Rotate the Frequency Direction to set the hour portion.
3) Press the M key.
4) Rotate the Frequency Coven knob to set the minute portion.
5) Press M-key to store exit.
Opening and closing of the switch timer
In the clock display mode, press the F key, press 5 to turn the timing boot function, indicator Timer.on will also light or go out.
In the clock display mode, press the F key, press 8 key, turn the timing shutdown function, indicator Timer.off will also light or go out.
Automatic boot warning
In the clock mode, press the F key, then press 6., automatically boot warning open, when the time is automatically turned on, the machine will issue an alert sound and last for 7 minutes. You can stop the alerts in the front panel.
[Cross-band operation]
Cross-band operation is to allow you to receive in the UHF band, while in the VHF wave section (for TH-28A); or in turn (for TH-48A).
The following uses TH-48A as an example how to operate: (Translator Note - the original is TH-28A as an example)
1) Press the BAND button to switch to the sub-band.
2) Set a received frequency using the FM knob or the numeric key, this example is: 145.660 MHz.
3) Press the BAND button.
4) Rotate the Frequency Cathode or use the numeric keys to set a transmit frequency, this example is: 438.100 MHz.
5) Press the F button and press the BAND button. The cross-band indicator lights up and displays the receiving frequency, this example is: 145.660 MHz. You can change this frequency using the frequency band knob.
6) Now pressing the PTT button You can fire in the UHF band.
Perform cross-channel operations using channel mode
1) You must set the reception frequency as a sub-band and set the transmit frequency as the main band.
2) Select the channel you want to store.